ML
    • Recent
    • Categories
    • Tags
    • Popular
    • Users
    • Groups
    • Register
    • Login

    One Server -2 NICs, Different IPs

    IT Discussion
    13
    33
    2.0k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • ObsolesceO
      Obsolesce
      last edited by

      It very well could be that the server had several network ports, and someone just figured they all aught to all be plugged in... just out of ignorance. I'd see what traffic is on them as I said above. Or what you said, just ask them why.

      1 Reply Last reply Reply Quote 3
      • F
        frodooftheshire @Obsolesce
        last edited by

        @Tim_G That's a good idea. I'm pretty sure it was ignorance. I mean...they have a Windows server and installed the DHCP role, but did not configure it. DNS is somewhat configured correctly but all the endpoints are pointing to Comcast's DNS servers...soooo.

        JaredBuschJ 1 Reply Last reply Reply Quote 4
        • JaredBuschJ
          JaredBusch @frodooftheshire
          last edited by

          @frodooftheshire said in One Server -2 NICs, Different IPs:

          but all the endpoints are pointing to Comcast's DNS servers

          I'm sooo sorry.

          1 Reply Last reply Reply Quote 4
          • IRJI
            IRJ
            last edited by

            As much as I am against downtime, I might unplug the second NIC. If there is an issue, it just needs to be plugged back in. If there isn't an issue for a month, you can team the NICS.

            If you don't really see any traffic on the second NIC. So what is the actual risk? perhaps downtime, but all you need to do is plug it back in if there is an issue.

            1 Reply Last reply Reply Quote 1
            • IRJI
              IRJ
              last edited by

              At the end of the day, you can spend hours trying to figure this out or you can save the customer money and find out if it is needed prettty easily.

              DashrenderD 1 Reply Last reply Reply Quote 2
              • DashrenderD
                Dashrender @IRJ
                last edited by

                @IRJ said in One Server -2 NICs, Different IPs:

                At the end of the day, you can spend hours trying to figure this out or you can save the customer money and find out if it is needed prettty easily.

                Exactly - Though just a CYA, tell the management you are doing that, and let them say it's OK to save the money that way...

                1 Reply Last reply Reply Quote 0
                • GreyG
                  Grey
                  last edited by

                  If the IPs are on the same subnet, it's doing more harm than good. Traffic coming in on one NIC will go out the other. Windows likes to use the lowest IP address to send data out. If you receive on 56, it will go out on 55. I've seen this happen. We have wireshark logs.

                  I would suggest you immediately remove or team the spare nic to increase throughput. Be sure that your network hardware supports that!

                  You can do a route print from the command line to see which nic is dominant.

                  @frodooftheshire said in One Server -2 NICs, Different IPs:

                  @Tim_G I could always disable the port on the switch and if the screams come in switch it back on. Like most clients I take on the customer has zero documentation on how things are setup/configured. Maybe I'll be able to have a conversation with the old IT guy and see if he's willing to share on why things the way they are.

                  I'm working in an environment now with this kind of bullshit and it's almost 100% because the previous admins were /idiots./

                  1 Reply Last reply Reply Quote 0
                  • Reid CooperR
                    Reid Cooper
                    last edited by

                    If you can find a non-critical time frame it might well be worth just shutting one of them off and seeing what breaks. If nothing, leave it off.

                    1 Reply Last reply Reply Quote 0
                    • F
                      frodooftheshire
                      last edited by frodooftheshire

                      Ok guys...update from today:
                      After going through things more, apparently both adapters were "bridged" via a Microsoft virtual adapter in Windows giving the "switch"a 51.6 IP address. This makes zero sense to me. Considering both ports were connected to the same Cisco router - potentially there could have been some switch/loop issues.

                      Anyways, I ended up disabling the "virtual switch" & secondary NIC (for now). I also found out that there was another small switch that was connecting to another network (from another business) in the building that had a Comcast gateway with its DHCP server turned on - handing out addresses in 10.1.10.X range. Fun stuff.

                      Anyways things seem to be working well now.

                      scottalanmillerS DashrenderD 2 Replies Last reply Reply Quote 2
                      • Deleted74295D
                        Deleted74295 Banned
                        last edited by

                        Until it goes wrong.

                        You would not believe the situations people get themselves into by just unplugging things when they are not 100% certain of what is going where.

                        Did you check the Cisco Router config to see if there was anything particular about those ports?

                        scottalanmillerS 1 Reply Last reply Reply Quote 0
                        • scottalanmillerS
                          scottalanmiller @Deleted74295
                          last edited by

                          @Breffni-Potter said in One Server -2 NICs, Different IPs:

                          Until it goes wrong.

                          You would not believe the situations people get themselves into by just unplugging things when they are not 100% certain of what is going where.

                          Did you check the Cisco Router config to see if there was anything particular about those ports?

                          If unplugging it causes a huge disaster outside of production hours, it was going to happen sooner or later anyway. Network connections get unplugged, switches reboot, cables break, etc.

                          1 Reply Last reply Reply Quote 0
                          • scottalanmillerS
                            scottalanmiller @frodooftheshire
                            last edited by

                            @frodooftheshire yeah switch to switch like that isn't good. What a mess.

                            1 Reply Last reply Reply Quote 0
                            • DashrenderD
                              Dashrender @frodooftheshire
                              last edited by

                              @frodooftheshire said in One Server -2 NICs, Different IPs:

                              Ok guys...update from today:
                              After going through things more, apparently both adapters were "bridged" via a Microsoft virtual adapter in Windows giving the "switch"a 51.6 IP address. This makes zero sense to me. Considering both ports were connected to the same Cisco router - potentially there could have been some switch/loop issues.

                              Anyways, I ended up disabling the "virtual switch" & secondary NIC (for now). I also found out that there was another small switch that was connecting to another network (from another business) in the building that had a Comcast gateway with its DHCP server turned on - handing out addresses in 10.1.10.X range. Fun stuff.

                              Anyways things seem to be working well now.

                              One just weird thing and another - WTF?

                              Why is the server plugged directly into a router and not a switch? I suppose if the situation is small enough and you have enough ports on the router (thinking ER-X here), OK maybe...

                              And someone else's network is connected to this network? How in the world did that happen? lol

                              Sounds like you are in for some good billing fixing someone else's mistakes.

                              1 Reply Last reply Reply Quote 1
                              • 1
                              • 2
                              • 2 / 2
                              • First post
                                Last post