ML
    • Recent
    • Categories
    • Tags
    • Popular
    • Users
    • Groups
    • Register
    • Login

    Server will not shut down

    IT Discussion
    windows server 2012 r2 multiple nics
    8
    58
    5.8k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • DustinB3403D
      DustinB3403 @dafyre
      last edited by DustinB3403

      @dafyre said in Server will not shut down:

      @DustinB3403 said in Server will not shut down:

      Hrm. . .

      Are you using the RDP connection option from within XenCenter to connect to these systems? (still investigating the shared resources item mentioned above.)

      This is running on VMware. 🙂

      We are connecting to them via RDP and the VMware console. Neither makes any difference.

      Yeah I realized I was a few minutes behind the ball after posting. So ignore me.

      1 Reply Last reply Reply Quote 1
      • scottalanmillerS
        scottalanmiller @dafyre
        last edited by

        @dafyre said in Server will not shut down:

        Got an oddball problem here... We are working on setting up several VM clones for a project here. Each VM will be connected to the same shared storage via iSCSI.

        Under the hood, right? Via the datastore, not iSCSI connecting to the OS inside of the VM, right?

        scottalanmillerS 1 Reply Last reply Reply Quote 1
        • scottalanmillerS
          scottalanmiller @dafyre
          last edited by

          @dafyre said in Server will not shut down:

          No, we don't have anything running on them yet. The iSCSI initiator service is the only thing that has been set up, and our usual disable IEC, and UAC type stuff.

          Otherwise, it is a basic Server 2012 R2 install.

          Why use iSCSI from inside of the VM?

          dafyreD 1 Reply Last reply Reply Quote 0
          • JaredBuschJ
            JaredBusch
            last edited by

            Why 4 vCPU each? That seems excessive.

            dafyreD 1 Reply Last reply Reply Quote 3
            • scottalanmillerS
              scottalanmiller
              last edited by

              Given the setup, my inkling is that you have an issue with the iSCSI Initiator. The Microsoft iSCSI Initiator is known to be flaky and can easily be causing an issue. Both architecturally and practically due to the use of Windows it is standard practice to present SAN storage as a local drive via VMware to the VM rather than inside of the VM. VMware's handling of iSCSI is much more robust than Windows is, and you need only one connection per physical host rather than one per VM.

              dafyreD 1 Reply Last reply Reply Quote 2
              • dafyreD
                dafyre @JaredBusch
                last edited by

                @JaredBusch said in Server will not shut down:

                Why 4 vCPU each? That seems excessive.

                Agreed. We don't expect the software to use that much, but we're building it to the specs that our vendor has requested.

                scottalanmillerS 1 Reply Last reply Reply Quote 0
                • scottalanmillerS
                  scottalanmiller @dafyre
                  last edited by

                  @dafyre said in Server will not shut down:

                  @JaredBusch said in Server will not shut down:

                  Why 4 vCPU each? That seems excessive.

                  Agreed. We don't expect the software to use that much, but we're building it to the specs that our vendor has requested.

                  With virtualization that can cause performance problems. The vendor may be injecting a mistake here. Having more cores than are needed will degrade performance. And... can cause lockups in rare cases.

                  1 Reply Last reply Reply Quote 0
                  • dafyreD
                    dafyre @scottalanmiller
                    last edited by

                    @scottalanmiller said in Server will not shut down:

                    @dafyre said in Server will not shut down:

                    No, we don't have anything running on them yet. The iSCSI initiator service is the only thing that has been set up, and our usual disable IEC, and UAC type stuff.

                    Otherwise, it is a basic Server 2012 R2 install.

                    Why use iSCSI from inside of the VM?

                    Because it works that way?

                    That's the way I would set it up. Although this time, I'm actually not the one who set up the master image. We're connecting to a SAN to store large amounts of video for security cameras.

                    scottalanmillerS 2 Replies Last reply Reply Quote 0
                    • scottalanmillerS
                      scottalanmiller @dafyre
                      last edited by

                      @dafyre said in Server will not shut down:

                      Why use iSCSI from inside of the VM?

                      Because it works that way?

                      Well it doesn't work well that way and in this case, it's possible that it doesn't work at all 🙂

                      1 Reply Last reply Reply Quote 1
                      • scottalanmillerS
                        scottalanmiller @dafyre
                        last edited by

                        @dafyre said in Server will not shut down:

                        That's the way I would set it up. Although this time, I'm actually not the one who set up the master image. We're connecting to a SAN to store large amounts of video for security cameras.

                        I'm not questioning the SAN or the iSCSI. I'm questioning the configuration which is extremely complex and fragile compared to a more elegant, more modern configuration using VMware as designed.

                        1 Reply Last reply Reply Quote 0
                        • dafyreD
                          dafyre @scottalanmiller
                          last edited by

                          @scottalanmiller said in Server will not shut down:

                          Given the setup, my inkling is that you have an issue with the iSCSI Initiator. The Microsoft iSCSI Initiator is known to be flaky and can easily be causing an issue. Both architecturally and practically due to the use of Windows it is standard practice to present SAN storage as a local drive via VMware to the VM rather than inside of the VM. VMware's handling of iSCSI is much more robust than Windows is, and you need only one connection per physical host rather than one per VM.

                          I've set up shared storage with VMware before, and IIRC, isn't there a limit on the size of the disk image that you can set up? Our VMware disk images would be ~20 TB each.

                          scottalanmillerS 1 Reply Last reply Reply Quote 0
                          • scottalanmillerS
                            scottalanmiller @dafyre
                            last edited by

                            @dafyre said in Server will not shut down:

                            I've set up shared storage with VMware before, and IIRC, isn't there a limit on the size of the disk image that you can set up? Our VMware disk images would be ~20 TB each.

                            62TB

                            dafyreD 1 Reply Last reply Reply Quote 0
                            • dafyreD
                              dafyre @scottalanmiller
                              last edited by

                              @scottalanmiller said in Server will not shut down:

                              @dafyre said in Server will not shut down:

                              I've set up shared storage with VMware before, and IIRC, isn't there a limit on the size of the disk image that you can set up? Our VMware disk images would be ~20 TB each.

                              62TB

                              Cool. I'll pass that info along and see if he wants to set it up that way.

                              scottalanmillerS 1 Reply Last reply Reply Quote 0
                              • scottalanmillerS
                                scottalanmiller @dafyre
                                last edited by

                                @dafyre said in Server will not shut down:

                                @scottalanmiller said in Server will not shut down:

                                @dafyre said in Server will not shut down:

                                I've set up shared storage with VMware before, and IIRC, isn't there a limit on the size of the disk image that you can set up? Our VMware disk images would be ~20 TB each.

                                62TB

                                Cool. I'll pass that info along and see if he wants to set it up that way.

                                Assuming you are not on some ancient VMware. It's been that big for a while.

                                I would take a "moment" and make one VM or two that use the "direct to VMware" SAN method and test that and see if it fixes things. It simplifies your setup by quite a bit and would be better for the long term. It's more efficient to the SAN, so might be very good for your performance, too. And avoiding that Windows component is always worth it. Just makes things simpler and more abstracted - leveraging virtualization for what it is built for.

                                1 Reply Last reply Reply Quote 0
                                • scottalanmillerS
                                  scottalanmiller
                                  last edited by

                                  It might not be the issue, but it's a place to start.

                                  dafyreD 1 Reply Last reply Reply Quote 0
                                  • dafyreD
                                    dafyre @scottalanmiller
                                    last edited by

                                    @scottalanmiller said in Server will not shut down:

                                    It might not be the issue, but it's a place to start.

                                    Seems legit, lol.

                                    I've done set ups using the iSCSI initiator before (I have two of them running here now -- Failover Clusters) and never had any problems at all. So something in this setup is the issue.

                                    scottalanmillerS 1 Reply Last reply Reply Quote 0
                                    • scottalanmillerS
                                      scottalanmiller @dafyre
                                      last edited by

                                      @dafyre said in Server will not shut down:

                                      @scottalanmiller said in Server will not shut down:

                                      It might not be the issue, but it's a place to start.

                                      Seems legit, lol.

                                      I've done set ups using the iSCSI initiator before (I have two of them running here now -- Failover Clusters) and never had any problems at all. So something in this setup is the issue.

                                      It has to work "most of the time" or they couldn't even include it. But like a lot of things in the Windows storage ecosystem (which includes Dynamic Disks, DFS and Software RAID), the iSCSI components are weak and fragile and can cause lots of issues. This is why companies like @StarWind_Software have taken the time to rewrite and replace those components for enterprise use because the built in ones just aren't up to the task. And now that Windows is "always" run as a VM and the standard pattern is using the SAN to the hypervisor, Microsoft has no reason to fix or improve what is included any longer. So now it is stagnating, as well.

                                      I've never tried Windows with iSCSI setup and cloned. I'm wondering if cloning iSCSI is part of the issue.

                                      dafyreD scottalanmillerS 2 Replies Last reply Reply Quote 2
                                      • dafyreD
                                        dafyre @scottalanmiller
                                        last edited by

                                        @scottalanmiller said in Server will not shut down:

                                        @dafyre said in Server will not shut down:

                                        @scottalanmiller said in Server will not shut down:

                                        It might not be the issue, but it's a place to start.

                                        Seems legit, lol.

                                        I've done set ups using the iSCSI initiator before (I have two of them running here now -- Failover Clusters) and never had any problems at all. So something in this setup is the issue.

                                        It has to work "most of the time" or they couldn't even include it. But like a lot of things in the Windows storage ecosystem (which includes Dynamic Disks, DFS and Software RAID), the iSCSI components are weak and fragile and can cause lots of issues. This is why companies like @StarWind_Software have taken the time to rewrite and replace those components for enterprise use because the built in ones just aren't up to the task. And now that Windows is "always" run as a VM and the standard pattern is using the SAN to the hypervisor, Microsoft has no reason to fix or improve what is included any longer. So now it is stagnating, as well.

                                        I've never tried Windows with iSCSI setup and cloned. I'm wondering if cloning iSCSI is part of the issue.

                                        I would use it if it worked badly. But it does work, and in my experience, when it works, it works well... Or it works so badly that it's not even usable.

                                        We're actually talking about the iSCSI stuff being in the clone now. We'll see what boss says when we all get back from lunch.

                                        scottalanmillerS 1 Reply Last reply Reply Quote 0
                                        • scottalanmillerS
                                          scottalanmiller @dafyre
                                          last edited by

                                          @dafyre said in Server will not shut down:

                                          I would use it if it worked badly. But it does work, and in my experience, when it works, it works well... Or it works so badly that it's not even usable.

                                          That could be what's happening here 😉

                                          dafyreD 1 Reply Last reply Reply Quote 0
                                          • DashrenderD
                                            Dashrender
                                            last edited by

                                            Yeah i was wondering if the cloned ISCSI stuff was the problem as well.

                                            Does each VM get it's own LUN on the SAN?

                                            1 Reply Last reply Reply Quote 1
                                            • 1
                                            • 2
                                            • 3
                                            • 1 / 3
                                            • First post
                                              Last post