ML
    • Recent
    • Categories
    • Tags
    • Popular
    • Users
    • Groups
    • Register
    • Login

    Dell Perc H710 predicted failure

    IT Discussion
    6
    21
    3.0k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • dbeatoD
      dbeato @dbeato
      last edited by

      @dbeato said in Dell Perc H710 predicted failure:

      @i3
      Make a backup of the System and then wait for the hard drive to fail or if it was Dell Support, what they will tell you to mark the drive as offline and then pull it and add the new drive and it will rebuild. You can also use a hotspare but it will add more problems for the rebuilding due to the nature of it.

      But I would just replace it...now

      1 Reply Last reply Reply Quote 0
      • travisdh1T
        travisdh1
        last edited by

        Like @JaredBusch already said, get the drive replaced now. Just make sure you have a good backup first.

        1 Reply Last reply Reply Quote 0
        • I
          i3
          last edited by

          Thank you for the replies. I do have a backup and I plan on replacing it ASAP. My question is best way to replace it.

          Fail the drive and let it rebuild or put new drive in allow it to be assigned as hot spare then fail bad drive immediately.

          My understanding is the first option would involve the array to be degraded and rebuilt taking significantly longer to rebuild and being vulnerable while rebuilding.

          Wouldn’t the second option copy the data off just the drive in question then take the bad drive offline?

          Currently the virtual disk is still healthy and the predicted failure disk is still working. Option two seems like less risk and a quicker repair.

          dbeatoD scottalanmillerS 4 Replies Last reply Reply Quote 0
          • dbeatoD
            dbeato @i3
            last edited by

            @i3 said in Dell Perc H710 predicted failure:

            array to be degraded and rebuilt taking significantly longer to rebuild and being vulnerable while rebuilding.
            Wouldn’t the second option copy the data off just the drive in question then take the bad drive offline?

            A hotspare will do a rebuild still.

            scottalanmillerS 1 Reply Last reply Reply Quote 0
            • JaredBuschJ
              JaredBusch
              last edited by

              I told you already. I did not think I used too many words.

              @jaredbusch said in Dell Perc H710 predicted failure:

              Mark the drive offline and swap it. Period.

              Nope, not too many words.

              1 Reply Last reply Reply Quote 0
              • JaredBuschJ
                JaredBusch
                last edited by

                You have a PERC, it is perfectly capable of a flat out blind swap. Manually marking it is just for your own jollies.

                1 Reply Last reply Reply Quote 1
                • scottalanmillerS
                  scottalanmiller @JaredBusch
                  last edited by

                  @jaredbusch said in Dell Perc H710 predicted failure:

                  Mark the drive offline and swap it. Period.

                  This, don't get weird or complicated. Anything other than this just adds effort and risk.

                  1 Reply Last reply Reply Quote 1
                  • scottalanmillerS
                    scottalanmiller @dbeato
                    last edited by

                    @dbeato said in Dell Perc H710 predicted failure:

                    @i3 said in Dell Perc H710 predicted failure:

                    array to be degraded and rebuilt taking significantly longer to rebuild and being vulnerable while rebuilding.
                    Wouldn’t the second option copy the data off just the drive in question then take the bad drive offline?

                    A hotspare will do a rebuild still.

                    Not always, hot spares don't always have the same clarity of action as a proper swap.

                    1 Reply Last reply Reply Quote 0
                    • scottalanmillerS
                      scottalanmiller @i3
                      last edited by

                      @i3 said in Dell Perc H710 predicted failure:

                      My understanding is the first option would involve the array to be degraded and rebuilt taking significantly longer to rebuild and being vulnerable while rebuilding.

                      This situation happens either way. Only the proper first method fixes it faster than the unnecessary second method. The hot spare method has no advantages, just isn't quite as clear and moves your drives to weird positions (which is fine, but why?)

                      1 Reply Last reply Reply Quote 1
                      • scottalanmillerS
                        scottalanmiller @i3
                        last edited by

                        @i3 said in Dell Perc H710 predicted failure:

                        Wouldn’t the second option copy the data off just the drive in question then take the bad drive offline?

                        No, that is not how a hot spare works. A hot spare is just sitting there doing nothing, waiting for a drive to fail.

                        1 Reply Last reply Reply Quote 0
                        • scottalanmillerS
                          scottalanmiller @i3
                          last edited by

                          @i3 said in Dell Perc H710 predicted failure:

                          Currently the virtual disk is still healthy and the predicted failure disk is still working. Option two seems like less risk and a quicker repair.

                          It just feels this way, but this is incorrect.

                          1 Reply Last reply Reply Quote 0
                          • I
                            i3
                            last edited by

                            Thank you for all the replies. I will proceed with the mark failed and swap.

                            Thanks again!

                            1 Reply Last reply Reply Quote 1
                            • I
                              i3
                              last edited by

                              Update: I had to clear the foreign config on the new drives, however, Open Manage would not display the "are you sure you want to clear the foreign config" message. It just went to a blank page. I had to uninstall OM and upgrade to the current version, then I was prompted about firmware and driver versions. To be safe I upgraded those as well, with reboots in between, took another system image failed the "bad drive" popped in a new one and the rebuild began. Completed in about 5 hours. All is working well.

                              Thank again all.

                              1 Reply Last reply Reply Quote 2
                              • BRRABillB
                                BRRABill @JaredBusch
                                last edited by

                                @jaredbusch said in Dell Perc H710 predicted failure:

                                Don’t wait don’t delay just fucking do it

                                You should start making tshirts with this quote

                                JaredBuschJ 1 Reply Last reply Reply Quote 1
                                • JaredBuschJ
                                  JaredBusch @BRRABill
                                  last edited by

                                  @brrabill said in Dell Perc H710 predicted failure:

                                  @jaredbusch said in Dell Perc H710 predicted failure:

                                  Don’t wait don’t delay just fucking do it

                                  You should start making tshirts with this quote

                                  Learn something today from your failure to reboot more did we?

                                  BRRABillB 1 Reply Last reply Reply Quote 0
                                  • BRRABillB
                                    BRRABill @JaredBusch
                                    last edited by

                                    @jaredbusch said in Dell Perc H710 predicted failure:

                                    @brrabill said in Dell Perc H710 predicted failure:

                                    @jaredbusch said in Dell Perc H710 predicted failure:

                                    Don’t wait don’t delay just fucking do it

                                    You should start making tshirts with this quote

                                    Learn something today from your failure to reboot more did we?

                                    Not really.

                                    Wouldn't have helped. Would have just messed up whatever weekend i did it on.

                                    1 Reply Last reply Reply Quote 0
                                    • BRRABillB
                                      BRRABill
                                      last edited by

                                      Still in favor of tshirts, however.

                                      1 Reply Last reply Reply Quote 1
                                      • 1
                                      • 2
                                      • 1 / 2
                                      • First post
                                        Last post