    Dell PERC Question (Server Down)

    IT Discussion
    17
    255
    144.6k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • DashrenderD
      Dashrender
      last edited by

      So what's the plan here? I see three possibilities.

      1. replace at least drive 0:0 with a new Edge drive
      2. replace the Perc
      3. replace SSDs with Dell drives.
      BRRABillB 1 Reply Last reply Reply Quote 0
      • BRRABillB
        BRRABill @Dashrender
        last edited by

        @Dashrender said

        They aren't? I thought was the whole point of these Edge drives - that they are compliant and don't have issues with Dell stuff.

        But what do I know?

        I'm not going to speak for anyone at EDGE or xByte. But it seems like there are pockets of issues.

        1 Reply Last reply Reply Quote 0
        • BRRABillB
          BRRABill @Dashrender
          last edited by

          @Dashrender said in Dell PERC Question (Server Down):

          So what's the plan here? I see three possibilities.

          1. replace at least drive 0:0 with a new Edge drive
          2. replace the Perc
          3. replace SSDs with Dell drives.

          I heard back from EDGE.

          Basically the tech said that while he has never seen this exact issue, he has seen issues that are almost identical, and that they have a special model of the drive I have (I have the 3X) to fix these issues.

          So, I am going to cross my fingers and give that a try.

          todd-at-xByteT 1 Reply Last reply Reply Quote 1
          • scottalanmillerS
            scottalanmiller
            last edited by

            That sounds promising.

            1 Reply Last reply Reply Quote 0
            • BRRABillB
              BRRABill
              last edited by

              I also want to emphasize that xByte is a great company to deal with. I would not hesitate to use them at any time.

              1 Reply Last reply Reply Quote 3
              • todd-at-xByteT
                todd-at-xByte @BRRABill
                last edited by

                Basically the tech said that while he has never seen this exact issue, he has seen issues that are almost identical, and that they have a special model of the drive I have (I have the 3X) to fix these issues.

                We(xByte) have not seen or tested the Edge 3X drives and before feeling comfortable with this solution we would need to fully test the drives in a variety of Dell servers and PERC controllers. In the interest of getting this fully resolved as soon as possible, we are going to replace the Edge drives with Dell branded Enterprise SSD's.

                BRRABillB DashrenderD 2 Replies Last reply Reply Quote 1
                • BRRABillB
                  BRRABill @todd-at-xByte
                  last edited by

                  See my post right above the one from @todd-at-xByte

                  What a great company. I seriously wouldn't look anywhere else for any DELL stuff you need.

                  1 Reply Last reply Reply Quote 2
                  • DashrenderD
                    Dashrender @todd-at-xByte
                    last edited by

                    @todd-at-xByte said in Dell PERC Question (Server Down):

                    Basically the tech said that while he has never seen this exact issue, he has seen issues that are almost identical, and that they have a special model of the drive I have (I have the 3X) to fix these issues.

                    We(xByte) have not seen or tested the Edge 3X drives and before feeling comfortable with this solution we would need to fully test the drives in a variety of Dell servers and PERC controllers. In the interest of getting this fully resolved as soon as possible, we are going to replace the Edge drives with Dell branded Enterprise SSD's.

                    Wow - awesome.

                    So what are you doing for future customers who want SSDs in Dell servers? Is the only option now the Dell SSDs?

                    DustinB3403D 1 Reply Last reply Reply Quote 1
                    • DustinB3403D
                      DustinB3403 @Dashrender
                      last edited by

                      @Dashrender I think both xByte and EDGE would likely look to do more testing before completely ending the relationship.

                      There is already a relationship there. . .

                      DashrenderD 1 Reply Last reply Reply Quote 0
                      • BRRABillB
                        BRRABill
                        last edited by

                        I imagine they will also look at my drives when I send them back and try to figure out what went wrong.

                        todd-at-xByteT 1 Reply Last reply Reply Quote 1
                        • todd-at-xByteT
                          todd-at-xByte @BRRABill
                          last edited by

                          @BRRABill said in Dell PERC Question (Server Down):

                          I imagine they will also look at my drives when I send them back and try to figure out what went wrong.

                          The drives will indeed go back to Edge. They have updated their firmware based on other cases like this in the past.

                          BRRABillB 1 Reply Last reply Reply Quote 2
                          • BRRABillB
                            BRRABill @todd-at-xByte
                            last edited by

                            @todd-at-xByte these were a new line of drives to begin with, right?

                            I think you just recently switched, right?

                            todd-at-xByteT 1 Reply Last reply Reply Quote 0
                            • todd-at-xByteT
                              todd-at-xByte @BRRABill
                              last edited by

                              @BRRABill said in Dell PERC Question (Server Down):

                              @todd-at-xByte these were a new line of drives to begin with, right?

                              I think you just recently switched, right?

                              Not exactly. Edge rebranded the 960 Boost Pro Plus drives we were selling to E3 to consolidate their line. Edge stated that the 960 E3's were exactly the same as their 960 Boost Pro Plus.

                              DashrenderD 1 Reply Last reply Reply Quote 1
                              • DashrenderD
                                Dashrender @DustinB3403
                                last edited by

                                @DustinB3403 said in Dell PERC Question (Server Down):

                                @Dashrender I think both xByte and EDGE would likely look to do more testing before completely ending the relationship.

                                There is already a relationship there. . .

                                Awww - well I meant they would suggest Dell's only as long as they hadn't tested and resolved any issues with the new E3s

                                1 Reply Last reply Reply Quote 0
                                • DashrenderD
                                  Dashrender @todd-at-xByte
                                  last edited by

                                  @todd-at-xByte said in Dell PERC Question (Server Down):

                                  @BRRABill said in Dell PERC Question (Server Down):

                                  @todd-at-xByte these were a new line of drives to begin with, right?

                                  I think you just recently switched, right?

                                  Not exactly. Edge rebranded the 960 Boost Pro Plus drives we were selling to E3 to consolidate their line. Edge stated that the 960 E3's were exactly the same as their 960 Boost Pro Plus.

                                  How long had/have you been selling the Boost Pro Plus drives? And were there ever any issues with them?

                                  1 Reply Last reply Reply Quote 0
                                  • BRRABillB
                                    BRRABill
                                    last edited by

                                    So, the array went bye-bye again. Actually, it was just drive 1:0. (I'm still wondering if there is just something off with that drive.)

                                    Anyway, I said, the hell with this, time to get these new DELL drives in there.

                                    So the array came up degraded (just running on 1:1). I Rebooted and went into the PERC config. I unplugged 1:0 (which was missing anyway), and plugged the DELL drive into 1:2. It instantly powered up, and the PERC config saw it. I added it as a hot spare, and it instantly started rebuilding. AWESOME!

                                    So I rebooted the server. As soon as the server rebooted, the LED on the DELL drive started blinking. Hmm, that's odd, I think. Of course an error comes up, saying drives are missing. I look at the DELL drive, no LEDs. WTF.

                                    I'll cut through the 2+ hours on support with DELL, trying everything. They basically said, the array is toast. Great.

                                    I have 2 more of these DELL SSDs, so I think, WTH, let me try one of them. I plug it in, and reboot a few times with it outside the array. Comes back. So the big test, try it with the array. I do the same steps. But this time when it reboots, the array stays up.

                                    AWESOME AWESOME AWESOME!

                                    It is still currently rebuilding, so we shall see where we get with this. I wonder if the one drive was just a lemon. DELL says no, but I think the results say otherwise.

                                    1 Reply Last reply Reply Quote 0
                                    • DashrenderD
                                      Dashrender
                                      last edited by

                                      you rebooted after it started a rebuild? That wasn't wise.

                                      BRRABillB 1 Reply Last reply Reply Quote 0
                                      • BRRABillB
                                        BRRABill @Dashrender
                                        last edited by

                                        @Dashrender said in Dell PERC Question (Server Down):

                                        you rebooted after it started a rebuild? That wasn't wise.

                                        That's what I have seen all the DELL techs do.

                                        I doubled checked tonight and that it definitely the supported way to go.

                                        scottalanmillerS 1 Reply Last reply Reply Quote 0
                                        • DashrenderD
                                          Dashrender
                                          last edited by

                                          it may be allowable, but seems like an unwise thing to do. For example, I would never do that on a RAID 5 array, all that math, one little bit gets messed up.. array is lost. kinda like what happened to you.

                                          BRRABillB 1 Reply Last reply Reply Quote 0
                                          • BRRABillB
                                            BRRABill @Dashrender
                                            last edited by

                                            @Dashrender said in Dell PERC Question (Server Down):

                                            it may be allowable, but seems like an unwise thing to do. For example, I would never do that on a RAID 5 array, all that math, one little bit gets messed up.. array is lost. kinda like what happened to you.

                                            Just on a few drives. For other drives, it worked fine.

                                            If you had to wait the whole time for it to rebuild, it would take forever. (Think of the really long RAID5 times @scottalanmiller has mentioned.)

                                            1 Reply Last reply Reply Quote 1