    • wrx7mW
      wrx7m @Jimmy9008
      last edited by

      @Jimmy9008 said in VLAN on Dell N4064 Stacked:

      I have have N3000 stack too. If I connect 1 * 10 GbE from the N4000 stack to 1 * 10 GbE on the N3000 stack, and set the interfaces to allow vLAN1 and vLAN20, on both stacks, will anything on each vLAN route though the 10 GbE to the other stacks respective vLAN? I guess like a dumb layer 2 switch being connected to another dumb switch, they just pass traffic irrespective of vLAN?

      It should.

      1 Reply Last reply Reply Quote 1
      • 1
        1337 @Jimmy9008
        last edited by

        @Jimmy9008
        It does if they are the same type of port (general or trunk).

        But it would better to use use two 10G links and bond them with LACP active on both switch stacks.

        J 1 Reply Last reply Reply Quote 0
        • J
          Jimmy9008 @1337
          last edited by

          @Pete-S but would I still need to adding the two vLAN to that bonding?

          1 Reply Last reply Reply Quote 0
          • J
            Jimmy9008
            last edited by

            Or would that act like the stacking module with traffic just passed?

            1 Reply Last reply Reply Quote 0
            • 1
              1337
              last edited by 1337

              @Jimmy9008
              Yes, you have to add vlans to it.
              First select the interfaces you want to aggregate and make a channel-group (mode active). Then select the channel-group and add vlans to it. Do it on both stacks.

              If you want redundancy for switch failure you can put each port that is aggregated on different switches in the stack.

              Aggregating (bonding,teaming or whatever you want to call it) with LACP is just to make the connection between the switches redundant and load-balanced. It's still works logically like a single port.

              1 Reply Last reply Reply Quote 0
              • J
                Jimmy9008
                last edited by

                I'm at a point now where I have the three n4000 switch stacked together is one unit. Default/vLan1 is set.

                Also, the three n3000 are stacked together with default/vLan1 set.

                I have used link aggregation and hooked 10TbE 1 from N3000 switch 1 to 10TbE 1 in N4000 switch 1, and 10TbE 2 in N3000 switch 2 to 10TbE 1 in N4000 switch 2.

                Anything I put in to the N3000's can ping anything on the N4000s. Same the other way around. So the two stacks, and the LAG are working perfectly for the default/vLan1.

                Now, I can see where to create vLan2, that's fine. I can do that on both stacks. I just don't see how to get vLan2 to also be allowed over the LAG so clients on the vLan2 on either switch can talk. I'd like say interface 1 on N3000 unit 1 to be default/vLan1 if the device plugged in does not specify a vLan, if the device does specify vLan2, I want it to be able to get to a device on N4000 switch 1 interface 1 which is also set to vLan2...

                Any help would be appreciated....

                1 1 Reply Last reply Reply Quote 0
                • 1
                  1337 @Jimmy9008
                  last edited by 1337

                  @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                  I'm at a point now where I have the three n4000 switch stacked together is one unit. Default/vLan1 is set.

                  Also, the three n3000 are stacked together with default/vLan1 set.

                  I have used link aggregation and hooked 10TbE 1 from N3000 switch 1 to 10TbE 1 in N4000 switch 1, and 10TbE 2 in N3000 switch 2 to 10TbE 1 in N4000 switch 2.

                  Anything I put in to the N3000's can ping anything on the N4000s. Same the other way around. So the two stacks, and the LAG are working perfectly for the default/vLan1.

                  Now, I can see where to create vLan2, that's fine. I can do that on both stacks. I just don't see how to get vLan2 to also be allowed over the LAG so clients on the vLan2 on either switch can talk. I'd like say interface 1 on N3000 unit 1 to be default/vLan1 if the device plugged in does not specify a vLan, if the device does specify vLan2, I want it to be able to get to a device on N4000 switch 1 interface 1 which is also set to vLan2...

                  Any help would be appreciated....

                  The LAG has a name like Po1 right?
                  You need to add the vlans to the port-channel (Po1).

                  Do show vlan so see what you have configured.

                  Right now you'll only see the default vlan 1 on the LAG.

                  J 1 Reply Last reply Reply Quote 0
                  • J
                    Jimmy9008 @1337
                    last edited by

                    @Pete-S said in VLAN on Dell N4064 Stacked:

                    @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                    I'm at a point now where I have the three n4000 switch stacked together is one unit. Default/vLan1 is set.

                    Also, the three n3000 are stacked together with default/vLan1 set.

                    I have used link aggregation and hooked 10TbE 1 from N3000 switch 1 to 10TbE 1 in N4000 switch 1, and 10TbE 2 in N3000 switch 2 to 10TbE 1 in N4000 switch 2.

                    Anything I put in to the N3000's can ping anything on the N4000s. Same the other way around. So the two stacks, and the LAG are working perfectly for the default/vLan1.

                    Now, I can see where to create vLan2, that's fine. I can do that on both stacks. I just don't see how to get vLan2 to also be allowed over the LAG so clients on the vLan2 on either switch can talk. I'd like say interface 1 on N3000 unit 1 to be default/vLan1 if the device plugged in does not specify a vLan, if the device does specify vLan2, I want it to be able to get to a device on N4000 switch 1 interface 1 which is also set to vLan2...

                    Any help would be appreciated....

                    The LAG has a name like Po1 right?
                    You need to add the vlans to the port-channel.

                    I'll take a look for it and see if I can find that. On a train at the moment.

                    1 1 Reply Last reply Reply Quote 0
                    • J
                      Jimmy9008
                      last edited by

                      The LAG should be general mode or trunk mode? I guess general, as I've read trunk move only allows tagged traffic to flow. General seems to allow tagged and untagged...

                      1 1 Reply Last reply Reply Quote 0
                      • 1
                        1337 @Jimmy9008
                        last edited by 1337

                        @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                        The LAG should be general mode or trunk mode? I guess general, as I've read trunk move only allows tagged traffic to flow. General seems to allow tagged and untagged...

                        Don't think it matters between switches. Traffic always belong to a vlan anyway (even if it is untagged). You can set both to trunk.

                        1 Reply Last reply Reply Quote 0
                        • 1
                          1337 @Jimmy9008
                          last edited by

                          @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                          @Pete-S said in VLAN on Dell N4064 Stacked:

                          @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                          I'm at a point now where I have the three n4000 switch stacked together is one unit. Default/vLan1 is set.

                          Also, the three n3000 are stacked together with default/vLan1 set.

                          I have used link aggregation and hooked 10TbE 1 from N3000 switch 1 to 10TbE 1 in N4000 switch 1, and 10TbE 2 in N3000 switch 2 to 10TbE 1 in N4000 switch 2.

                          Anything I put in to the N3000's can ping anything on the N4000s. Same the other way around. So the two stacks, and the LAG are working perfectly for the default/vLan1.

                          Now, I can see where to create vLan2, that's fine. I can do that on both stacks. I just don't see how to get vLan2 to also be allowed over the LAG so clients on the vLan2 on either switch can talk. I'd like say interface 1 on N3000 unit 1 to be default/vLan1 if the device plugged in does not specify a vLan, if the device does specify vLan2, I want it to be able to get to a device on N4000 switch 1 interface 1 which is also set to vLan2...

                          Any help would be appreciated....

                          The LAG has a name like Po1 right?
                          You need to add the vlans to the port-channel.

                          I'll take a look for it and see if I can find that. On a train at the moment.

                          it's something like (going by memory)

                          interface po1
                          switchport general allowed vlan add 2 tagged
                          
                          J 1 Reply Last reply Reply Quote 0
                          • J
                            Jimmy9008 @1337
                            last edited by

                            @Pete-S can you only do this through the console/com?

                            1 1 Reply Last reply Reply Quote 0
                            • 1
                              1337 @Jimmy9008
                              last edited by 1337

                              @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                              @Pete-S can you only do this through the console/com?

                              I think you can do it through the gui as well. It's a pretty basic requirement if you think about it - sharing vlans between switches.

                              1 Reply Last reply Reply Quote 1
                              • J
                                Jimmy9008
                                last edited by

                                N4000 SW1 vLAN2.PNG N4000 SW1 Te111.PNG N4000 SW1 PO1.PNG N4000 SW1 Int 3 General.PNG N4000 SW1 Default vLAN.PNG

                                1 Reply Last reply Reply Quote 0
                                • J
                                  Jimmy9008
                                  last edited by

                                  So, thats how the N4000 is setup, see any issues? VLAN2 in top image has int 4 (Te3) set to T, for tagged traffic (anything I plug in will have vlan 2 set in the NIC). [First image].

                                  Second image shows Te/1/1/1, which is LAG port. Its set to general to pass all vlans. (I think). Image 3 shows Po1.

                                  Image 4 shows Interface 3 switch 1, which is also set to General.

                                  Image 5 shows default vLAN. Te3 is 'u'. So anything plugged in to te3, if not set to vLAN 2 should be in U on vlan1?

                                  1 1 Reply Last reply Reply Quote 0
                                  • 1
                                    1337 @Jimmy9008
                                    last edited by 1337

                                    @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                                    Second image shows Te/1/1/1, which is LAG port. Its set to general to pass all vlans. (I think). Image 3 shows Po1.

                                    LAG is not named Te1/1/1, it's an ordinary port (could be a member of a LAG group).

                                    Look under Link Aggregation.

                                    Or activate the freakin ssh port 🙂

                                    1 Reply Last reply Reply Quote 0
                                    • J
                                      Jimmy9008
                                      last edited by

                                      LAG.PNG

                                      1 Reply Last reply Reply Quote 0
                                      • J
                                        Jimmy9008
                                        last edited by

                                        Thats the LAG page. So unit 1, Te1/1 is LAG1. Unit 2, Te1/1 is LAG1 (both N4000). Then on the N3000 it has the same where Unit1 Te/1 and Unit2 Te/1 are LAG1. Traffic passes over these perfectly for vlan1.

                                        1 1 Reply Last reply Reply Quote 0
                                        • 1
                                          1337 @Jimmy9008
                                          last edited by 1337

                                          @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                                          Thats the LAG page. So unit 1, Te1/1 is LAG1. Unit 2, Te1/1 is LAG1 (both N4000). Then on the N3000 it has the same where Unit1 Te/1 and Unit2 Te/1 are LAG1. Traffic passes over these perfectly for vlan1.

                                          Perfect, then goto VLAN, VLAN members and select vlan 2. The click so you get vlan 2 on LAG 1.
                                          Now the LAG 1 will pass VLAN 2 as well.

                                          J 1 Reply Last reply Reply Quote 0
                                          • J
                                            Jimmy9008 @1337
                                            last edited by

                                            @Pete-S said in VLAN on Dell N4064 Stacked:

                                            @Jimmy9008 said in VLAN on Dell N4064 Stacked:

                                            Thats the LAG page. So unit 1, Te1/1 is LAG1. Unit 2, Te1/1 is LAG1 (both N4000). Then on the N3000 it has the same where Unit1 Te/1 and Unit2 Te/1 are LAG1. Traffic passes over these perfectly for vlan1.

                                            Perfect, then goto VLAN, VLAN members and select vlan 2. The click so you get vlan 2 on LAG 1.
                                            Now the LAG 1 will pass VLAN 2 as well.

                                            Click Te1/1/1 on vlan2 to say 'U'?