    hyper-v bad physical NIC? - vswitch or NIC teaming?

    IT Discussion
    5
    25
    2.5k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • coliverC
      coliver @Mike Davis
      last edited by

      @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

      @coliver said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

      I don't know if I would deploy something with known bad hardware into an environment that a tech would have trouble accessing.

      I don't want to either. I need to be absolutely sure what exactly is wrong. I shouldn't have said work around in the sense that it would be permanent. More of something like cut it over to the second NIC and make sure it's not a software bug.

      That's a good way to test. But I wouldn't deploy it like that.

      1 Reply Last reply Reply Quote 0
      • black3dynamiteB
        black3dynamite
        last edited by

        Is the NIC drivers up to date?

        Mike DavisM 1 Reply Last reply Reply Quote 0
        • Mike DavisM
          Mike Davis @black3dynamite
          last edited by

          @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

          Is the NIC drivers up to date?

          First thing I did was update the firmware for everything and all the drivers.

          black3dynamiteB 1 Reply Last reply Reply Quote 0
          • Mike DavisM
            Mike Davis
            last edited by

            Other troubleshooting that I did was cranked up iperf and ran a few GB through it. It didn't drop a beat.

            1 Reply Last reply Reply Quote 0
            • black3dynamiteB
              black3dynamite @Mike Davis
              last edited by

              @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

              @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

              Is the NIC drivers up to date?

              First thing I did was update the firmware for everything and all the drivers.

              Its possible Virtual Machine Queue (VMQ) could be causing the issue. Intel or Broadcom?

              Mike DavisM 1 Reply Last reply Reply Quote 0
              • Mike DavisM
                Mike Davis
                last edited by

                The only other thing I can think of is disabling the power management settings on the NIC, but I'm pretty sure I did that with the:
                Disable-NetAdapterPowerManagement -Name Ethernet
                command. The command
                Get-NetAdapterPowerManagement -Name Ethernet
                doesn't seem to show if it has been enabled or disabled, only the Wake on LAN. Does anyone know if there is another command to check the current status?

                black3dynamiteB 1 Reply Last reply Reply Quote 0
                • black3dynamiteB
                  black3dynamite @Mike Davis
                  last edited by

                  @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                  The only other thing I can think of is disabling the power management settings on the NIC, but I'm pretty sure I did that with the:
                  Disable-NetAdapterPowerManagement -Name Ethernet
                  command. The command
                  Get-NetAdapterPowerManagement -Name Ethernet
                  doesn't seem to show if it has been enabled or disabled, only the Wake on LAN. Does anyone know if there is another command to check the current status?

                  PS C:\Windows\system32> powercfg /list
                  
                  Existing Power Schemes (* Active)
                  -----------------------------------
                  Power Scheme GUID: 381b4222-f694-41f0-9685-ff5bb260df2e  (Balanced)
                  Power Scheme GUID: 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c  (High performance) *
                  Power Scheme GUID: a1841308-3541-4fab-bc81-f71556f20b4a  (Power saver)
                  
                  Mike DavisM 1 Reply Last reply Reply Quote 0
                  • Mike DavisM
                    Mike Davis @black3dynamite
                    last edited by

                    @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                    Its possible Virtual Machine Queue (VMQ) could be causing the issue. Intel or Broadcom?

                    I'm not sure. I'll have to be onsite to find out. What are the symptoms of that? Would VMQ knock the host offline as well?

                    ObsolesceO 1 Reply Last reply Reply Quote 0
                    • Mike DavisM
                      Mike Davis @black3dynamite
                      last edited by

                      @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                      @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                      The only other thing I can think of is disabling the power management settings on the NIC, but I'm pretty sure I did that with the:
                      Disable-NetAdapterPowerManagement -Name Ethernet
                      command. The command
                      Get-NetAdapterPowerManagement -Name Ethernet
                      doesn't seem to show if it has been enabled or disabled, only the Wake on LAN. Does anyone know if there is another command to check the current status?

                      PS C:\Windows\system32> powercfg /list
                      
                      Existing Power Schemes (* Active)
                      -----------------------------------
                      Power Scheme GUID: 381b4222-f694-41f0-9685-ff5bb260df2e  (Balanced)
                      Power Scheme GUID: 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c  (High performance) *
                      Power Scheme GUID: a1841308-3541-4fab-bc81-f71556f20b4a  (Power saver)
                      

                      That command may work for some stuff on the host, but I tested it on another server and it doesn't change the power settings for the individual NICs. cool command though.

                      black3dynamiteB 1 Reply Last reply Reply Quote 0
                      • black3dynamiteB
                        black3dynamite @Mike Davis
                        last edited by

                        @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                        @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                        @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                        The only other thing I can think of is disabling the power management settings on the NIC, but I'm pretty sure I did that with the:
                        Disable-NetAdapterPowerManagement -Name Ethernet
                        command. The command
                        Get-NetAdapterPowerManagement -Name Ethernet
                        doesn't seem to show if it has been enabled or disabled, only the Wake on LAN. Does anyone know if there is another command to check the current status?

                        PS C:\Windows\system32> powercfg /list
                        
                        Existing Power Schemes (* Active)
                        -----------------------------------
                        Power Scheme GUID: 381b4222-f694-41f0-9685-ff5bb260df2e  (Balanced)
                        Power Scheme GUID: 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c  (High performance) *
                        Power Scheme GUID: a1841308-3541-4fab-bc81-f71556f20b4a  (Power saver)
                        

                        That command may work for some stuff on the host, but I tested it on another server and it doesn't change the power settings for the individual NICs. cool command though.

                        Which power scheme is active? I've always make sure mine is set to High performance.

                        Mike DavisM 1 Reply Last reply Reply Quote 0
                        • ObsolesceO
                          Obsolesce @Mike Davis
                          last edited by Obsolesce

                          @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                          @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                          Its possible Virtual Machine Queue (VMQ) could be causing the issue. Intel or Broadcom?

                          I'm not sure. I'll have to be onsite to find out. What are the symptoms of that? Would VMQ knock the host offline as well?

                          Yes. This is a well known issue in an older firmware of some 1gig nics, such as broadcoms. Updating the firmware resolves the issue, or turning off VMQ, which you can do via powershell on Hyper-V Server 2016.

                          VMQ is meant for 10gig+ NICs, but the firmware is messed up and has it on by default on some 1gig nics.

                          ObsolesceO 1 Reply Last reply Reply Quote 0
                          • Mike DavisM
                            Mike Davis @black3dynamite
                            last edited by

                            @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                            Which power scheme is active? I've always make sure mine is set to High performance.

                            High performance. On the host I checked, it's a GUI install, so I went to the nic properties and I can still see Power Management tab and the box for "Allow the computer to turn off this device to save power" is still checked.

                            When you do: Disable-NetAdapterPowerManagement -Name Ethernet
                            it removes that tab.

                            1 Reply Last reply Reply Quote 0
                            • ObsolesceO
                              Obsolesce @Obsolesce
                              last edited by

                              @tim_g said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                              @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                              @black3dynamite said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                              Its possible Virtual Machine Queue (VMQ) could be causing the issue. Intel or Broadcom?

                              I'm not sure. I'll have to be onsite to find out. What are the symptoms of that? Would VMQ knock the host offline as well?

                              Yes. This is a well known issue in an older firmware of some 1gig nics, such as broadcoms. Updating the firmware resolves the issue, or turning off VMQ, which you can do via powershell on Hyper-V Server 2016.

                              VMQ is meant for 10gig NICs, but the firmware is messed up and has it on by default on some 1gig nics.

                              Here's some PS to get you started:

                              Get-NetAdapter
                              
                              Get-NetAdapterAdvancedProperty NIC1
                              
                              Get-NetAdapterAdvancedProperty * -DisplayName “Virtual Machine Queues”
                              
                              Set-NetAdapterAdvancedProperty * -DisplayName “Virtual Machine Queues” -DisplayValue Disabled
                              
                              Mike DavisM 1 Reply Last reply Reply Quote 0
                              • Mike DavisM
                                Mike Davis @Obsolesce
                                last edited by

                                @tim_g Thanks for the commands. If I get the output below, does that mean my NICs don't have the option for VMQ?

                                PS C:\> Get-NetAdapter
                                
                                Name                      InterfaceDescription                    ifIndex Statu
                                                                                                          s
                                ----                      --------------------                    ------- -----
                                vEthernet (vSwitch02)     Hyper-V Virtual Ethernet Adapter #3          29 Up
                                vEthernet (Broadcom BC... Hyper-V Virtual Ethernet Adapter #2          18 Up
                                Ethernet 2                HP NC373i Multifunction Gigabit S...#40      13 Up
                                Ethernet                  HP NC373i Multifunction Gigabit S...#39      12 Di...
                                
                                
                                PS C:\> Get-NetAdapterAdvancedProperty Ethernet
                                
                                Name                      DisplayName                    DisplayValue
                                ----                      -----------                    ------------
                                Ethernet                  Flow Control                   Auto
                                Ethernet                  Interrupt Moderation           Enabled
                                Ethernet                  Jumbo Packet                   1514
                                Ethernet                  Large Send Offload V2 (IPv4)   Enabled
                                Ethernet                  Maximum Number of RSS Queues   2
                                Ethernet                  Priority & VLAN                Priority & VLAN ena...
                                Ethernet                  Receive Buffers (0=Auto)       0
                                Ethernet                  Receive Side Scaling           Enabled
                                Ethernet                  Speed & Duplex                 Auto Negotiation
                                Ethernet                  TCP Connection Offload (IPv4)  Disabled
                                Ethernet                  TCP/UDP Checksum Offload (I... Rx & Tx Enabled
                                Ethernet                  Transmit Buffers (0=Auto)      0
                                Ethernet                  Wake On Magic Packet           Disabled
                                Ethernet                  Wake On Pattern Match          Disabled
                                Ethernet                  Locally Administered Address   --
                                Ethernet                  VLAN ID                        0
                                Ethernet                  Ethernet@WireSpeed             Enabled
                                
                                
                                PS C:\> Get-NetAdapterAdvancedProperty * -DisplayName "Virtual Machine Queues"
                                Get-NetAdapterAdvancedProperty : No matching
                                MSFT_NetAdapterAdvancedPropertySettingData objects found by CIM query for
                                instances of the ROOT/StandardCimv2/MSFT_NetAdapterAdvancedPropertySettingData
                                class on the  CIM server: SELECT * FROM
                                MSFT_NetAdapterAdvancedPropertySettingData  WHERE ((Name LIKE '%')) AND
                                ((DisplayName LIKE 'Virtual Machine Queues')). Verify query parameters and
                                retry.
                                At line:1 char:1
                                + Get-NetAdapterAdvancedProperty * -DisplayName "Virtual Machine Queues"
                                + ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
                                    + CategoryInfo          : ObjectNotFound: (MSFT_NetAdapter...ertySettingDa
                                   ta:String) [Get-NetAdapterAdvancedProperty], CimJobException
                                    + FullyQualifiedErrorId : CmdletizationQuery_NotFound,Get-NetAdapterAdvanc
                                   edProperty
                                
                                PS C:\>
                                
                                ObsolesceO 1 Reply Last reply Reply Quote 0
                                • ObsolesceO
                                  Obsolesce @Mike Davis
                                  last edited by

                                  @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                                  @tim_g Thanks for the commands. If I get the output below, does that mean my NICs don't have the option for VMQ?

                                  PS C:\> Get-NetAdapter
                                  
                                  Name                      InterfaceDescription                    ifIndex Statu
                                                                                                            s
                                  ----                      --------------------                    ------- -----
                                  vEthernet (vSwitch02)     Hyper-V Virtual Ethernet Adapter #3          29 Up
                                  vEthernet (Broadcom BC... Hyper-V Virtual Ethernet Adapter #2          18 Up
                                  Ethernet 2                HP NC373i Multifunction Gigabit S...#40      13 Up
                                  Ethernet                  HP NC373i Multifunction Gigabit S...#39      12 Di...
                                  
                                  
                                  PS C:\> Get-NetAdapterAdvancedProperty Ethernet
                                  
                                  Name                      DisplayName                    DisplayValue
                                  ----                      -----------                    ------------
                                  Ethernet                  Flow Control                   Auto
                                  Ethernet                  Interrupt Moderation           Enabled
                                  Ethernet                  Jumbo Packet                   1514
                                  Ethernet                  Large Send Offload V2 (IPv4)   Enabled
                                  Ethernet                  Maximum Number of RSS Queues   2
                                  Ethernet                  Priority & VLAN                Priority & VLAN ena...
                                  Ethernet                  Receive Buffers (0=Auto)       0
                                  Ethernet                  Receive Side Scaling           Enabled
                                  Ethernet                  Speed & Duplex                 Auto Negotiation
                                  Ethernet                  TCP Connection Offload (IPv4)  Disabled
                                  Ethernet                  TCP/UDP Checksum Offload (I... Rx & Tx Enabled
                                  Ethernet                  Transmit Buffers (0=Auto)      0
                                  Ethernet                  Wake On Magic Packet           Disabled
                                  Ethernet                  Wake On Pattern Match          Disabled
                                  Ethernet                  Locally Administered Address   --
                                  Ethernet                  VLAN ID                        0
                                  Ethernet                  Ethernet@WireSpeed             Enabled
                                  
                                  
                                  PS C:\> Get-NetAdapterAdvancedProperty * -DisplayName "Virtual Machine Queues"
                                  Get-NetAdapterAdvancedProperty : No matching
                                  MSFT_NetAdapterAdvancedPropertySettingData objects found by CIM query for
                                  instances of the ROOT/StandardCimv2/MSFT_NetAdapterAdvancedPropertySettingData
                                  class on the  CIM server: SELECT * FROM
                                  MSFT_NetAdapterAdvancedPropertySettingData  WHERE ((Name LIKE '%')) AND
                                  ((DisplayName LIKE 'Virtual Machine Queues')). Verify query parameters and
                                  retry.
                                  At line:1 char:1
                                  + Get-NetAdapterAdvancedProperty * -DisplayName "Virtual Machine Queues"
                                  + ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
                                      + CategoryInfo          : ObjectNotFound: (MSFT_NetAdapter...ertySettingDa
                                     ta:String) [Get-NetAdapterAdvancedProperty], CimJobException
                                      + FullyQualifiedErrorId : CmdletizationQuery_NotFound,Get-NetAdapterAdvanc
                                     edProperty
                                  
                                  PS C:\>
                                  

                                  Yeah you seem to be fine there. No VMQ.
                                  You could still try updating the firmware to see if that resolves the issue before replacing the NIC.

                                  Mike DavisM 1 Reply Last reply Reply Quote 0
                                  • ObsolesceO
                                    Obsolesce @Mike Davis
                                    last edited by

                                    @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                                    Given that, would it make the most sense to create a new vSwitch with the second NIC and add that to the VM and see if it stays up like that, or would NIC teaming be a better way to go?

                                    I wouldn't include a known bad NIC in a team. If that NIC is bad, disable it on the host if you can't switch it out. Create a new vSwitch from a working NIC and add that to the VM. You can use the same MAC if needed.

                                    1 Reply Last reply Reply Quote 0
                                    • Mike DavisM
                                      Mike Davis @Obsolesce
                                      last edited by

                                      @tim_g said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                                      @mike-davis said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                                      @tim_g Thanks for the commands. If I get the output below, does that mean my NICs don't have the option for VMQ?

                                      Yeah you seem to be fine there. No VMQ.
                                      You could still try updating the firmware to see if that resolves the issue before replacing the NIC.

                                      When I ran the commands in the output above that was on a spare non production server. I ran those commands last night on the problem server and it did have VMQ and it was enabled. I disabled it and it has been up 17 hours now. Before when it was failing, it would go down every 3-5 days, so I'll have to wait a few more days to know if the problem has been licked.

                                      1 Reply Last reply Reply Quote 0
                                      • dafyreD
                                        dafyre
                                        last edited by

                                        You can also try:

                                        get-netadaptervmq

                                        If you want to do a blanket disable of VMQ (which is what I usually do):

                                        get-netadaptervmq|disable-netadaptervmq

                                        What does the windows event log look like? (You said this was a gui install, right?)

                                        Mike DavisM 1 Reply Last reply Reply Quote 0
                                        • Mike DavisM
                                          Mike Davis @dafyre
                                          last edited by

                                          @dafyre said in hyper-v bad physical NIC? - vswitch or NIC teaming?:

                                          What does the windows event log look like? (You said this was a gui install, right?)

                                          My lab server is a GUI install, but the production server is non GUI.

                                          1 Reply Last reply Reply Quote 1
                                          • 1
                                          • 2
                                          • 1 / 2
                                          • First post
                                            Last post